Galaxy 2 Series Installation Manual
Visible alerts are given on the keypad display only.
24 = Entry Deviation
This parameter has two settings:
0.No
1. Yes (default)
If set to 0 (Entry Deviation not permitted), deviation from an entry route during entry or supplementary entry
periods will result in a Full Alarm Condition.
An entry route is defined as zones programmed as 01 (final) and 02 (exit).
Entry Deviation permitted (1) means that external bells/communications/triggers will be withheld until the entry
time expires. Entering a valid code before a full alarm condition prevents communication and triggers from
activating.
This option defaults to 1 - required by DD243, EN50131-1
25 = Easy Set
This parameter has two settings:
0. No (default)
1.Yes
When set to Yes (enabled), this option allows users to (Full, Part or Night) set the system without entering a
user code. Instead, users set the system by pressing the A> or B< Keys. A valid user code is still required to
unset the system.
When set to No (disabled), a user code must be entered before setting.
26 = Supplementary Entry
This parameter has two settings:
0. No
1.Yes
When set to No (disabled) an alarm condition occurs if the system has not been unset at the end of the entry
time.
When set to Yes (enabled) an internal only alarm occurs if the system has not been unset at the end of the
entry time (Trigger, External Bell and Strobe do not activate). The internal alarm will run for 30 seconds. A full
alarm will occur if the system has not been unset at the end of this time.
46 = Zone Resistance
This parameter has 3 options:
1. Zone Config
The zones on the Galaxy 2 Series function as Normally Closed, Double Balanced, End of Line. This sets the
configuration for all hardwire zones on the system, including expanders. See Section 5: Hardware—Zones,
for wiring instructions for each configuration.
0. Normally Closed
1. Double Balanced
51 - Parameters (cont’d)

Table of Contents

Other manuals for Honeywell Galaxy 2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy 2 Series and is the answer not in the manual?

Honeywell Galaxy 2 Series Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy 2 Series
CategorySecurity System
LanguageEnglish

Related product manuals