GX-Series Control Panel Installation and Setup Guide
6-69
Output Functions
Batt
Low Fire Horn
E/E
Horn Part Set Confirm
Line
Fail Video
Comm
Fail
Batt
Test
Wrong
CD Alert
DLYD
Fire
No Re-
arm
Zone Function 15 16 17 18 19 20 21 22 23 24 25 26 27 28
01 Final
- - S SXE - - - S - - - - - S
02 Exit
- - S SXE - S - S - - - - - S
03 Intruder
- - S SXE - S - S - - - - - S
04 24 Hours
- - S A - - - S - - - - - S
05 Security
- - S A - - - S - - - - - S
06 Dual
- - S SXE - S - S - - - - - S
07 Entry
- - S SXE - - - S - - - - - S
08 Push Set
- - - X - - - - - - - - - -
09 Keyswitch
- - - - X - - - - - - - - -
10 Secure Final
- - A A X S - S - - - - S -
11 Part Final
- - A SXE X S - S - - - - S -
12 Part Entry
- - A XE X S - S - - - - S -
13 PA
- - A - - - - - - - - - A -
14 PA Silent
- - A - - - - - - - - - A -
15 PA Delay
- - - - - - - - - - - - - -
16 PA Delay Silent
- - A A - - - - - - - - A -
17 Link
? ?
? ? ? ? ? ? ? ? ? ? ? ?
18 Spare
- - - - - - - - - - - - - -
19 Fire
- A A A - - - V - - - - A A
20 Tamper
- - A A - - - S - - - - - S
21 Bell Tamper
- - A A - - - S - - - - - S
22 Beam Pair
- - S SXE - - - S - - - - - S
23 Battery Low
U - - - - - - - - - - - - -
24 Line Fail
- - - U - - A - - - - - - -
25 AC Fail
- - - - - - - - - - - - - -
26 Log
- - - - - - - - - - - - - -
27 Remote Access
- - - - - - - - - - - - - -
28 Video
- - S SXE - S - S - - - - - S
29 Video Exit
- - S SXE - S - S - - - - - S
30 Intruder Delay
- - S SXE - - - S - - - - - S
31 Log Delay
- - - - - - - - - - - - - -
32 Set Log
- - - - - - - - - - - - - -
33 Custom-A
? ?
? ? ? ? ? ? ? ? ? ? ? ?
34 Custom-B
? ?
? ? ? ? ? ? ? ? ? ? ? ?
35 Exit Guard
L L L L L L L L L L L L L L
36 Mask
- - S SXE - - - S - - - - - S
37 Urgent
- - A A - - - - - - - - - A
38 PA Unset
- - - - - - - - - - - - - -
39 Keyswitch Reset
- - - - - - - - - - - - - -
40 Bell Fail
- - - - - - - - - - - - - -
41 Intr Low
- - S SXE - S - S - - - - - S
42 Intr High
- - S SXE - S - S - - - - - S
43 PSU Fault
- - - - - - - - - - - - - -
44-46 Not Used
- - - - - - - - - - - - - -
47 Vibration
- - - - - - - - - - - - - -
48 ATM-1
- - - - - - - - - - - - - -
49 ATM-2
- - - - - - - - - - - - - -
50 ATM-3
- - - - - - - - - - - - - -
51 ATM-4
- - - - - - - - - - - - - -
52 Alarm Extend
A A - A T - - - - - - A - -
Key:
S = Activates when system is set (armed)
P = Activates when system is Part set (Part armed)
U = Unset (disarmed)
A = Activated in any condition
- = No effect
? = Activation dependant on system programming
X = Activates during Exit Time
E = Activates during Entry
L = Switches output off if linked to destination output
T = Activates if zone resistance is less than value for tamper s/c or greater than value for tamper o/c
O = Activates when zone is omitted (bypassed)
Table 6-21. Output Activations per Zone

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell GX-Series and is the answer not in the manual?

Honeywell GX-Series Specifications

General IconGeneral
BrandHoneywell
ModelGX-Series
CategoryControl Panel
LanguageEnglish

Related product manuals