Returns this reply if the command is successful:
{SSC:U:0}
Returns this reply if there is an error:
{UST:S:error condition=X}
where error condition is:
Lid_Open: If Lid_Open=Y, the printer has detected an error condition and cancels any
pending print jobs.
Paper_Out: If Paper_Out=Y, the printer has detected an error condition and cancels
any pending print jobs.
Voltage:
If Voltage=H, the printer has detected a high voltage condition. No action is required;
the printer is just providing status that it has reached full voltage.
If Voltage=L, the printer has detected a low voltage condition. The battery voltage is
below the level set with the Set Low Battery Indicator command. Connect the printer
to external power to recharge battery.
You can receive several error conditions in the same string. For example, the printer
may send a command string in this format:
{UST:S:Lid_Open=Y,Paper_Out=Y,Voltage=H}
Quit ESC/P
Quits the ESC/P language application and enters Fingerprint.
Command
ESC{QUIT}
Restore Factory Defaults
Resets the printer to factory default values. You must follow the Restore Factory
Defaults command with the Commit command (ESC EZ{COMMIT}{LP}).
Command
ESC{SDV}ESC
This table lists the default values that are restored when you send this command.
Setting Default
RS-232 serial port
Baud rate 115200
64 EZ-Print Command Reference