Example
This command retrieves the values of the sleep and standby timers. The sleep timer is
set for 20 seconds and the standby timer is set for 30 minutes.
<ESC>{QST:PW}
Reply:
{QST:PW:20,30}
Set Dark Adjust
Sets the energy level for the printhead which controls how dark the print appears on the media.
Command
ESC{SSC:E:F1,F2}
where:
F1: The printhead Manufacturer ID. The printer supports K, S, and R.
F2: Sets the energy level for the printhead:
l
80 (lightest)
l
90
l
100 (default)
l
110
l
120
l
130
l
160 (darkest)
Example
This command sets the dark adjust on the printer to 100.
SC{SSC:E:S,100}
Returns this reply if the command is not successful:
{SSC:E:1}
Returns this reply if the command is successful:
{SSC:E:0}