EasyManuals Logo

HP 50G User Manual

HP 50G
887 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #583 background imageLoading...
Page #583 background image
Page 18-16
The DATA sub-menu
The DATA sub-menu contains functions used to manipulate the statistics matrix
ΣDATA:
The operation of these functions is as follows:
Σ+ : add row in level 1 to bottom of ΣDATA matrix.
Σ- : removes last row in ΣDATA matrix and places it in level of 1 of the stack.
The modified ΣDATA matrix remains in memory.
CLΣ : erases current ΣDATA matrix.
ΣDAT: places contents of current ΣDATA matrix in level 1 of the stack.
ΣDAT: stores matrix in level 1 of stack into ΣDATA matrix.
The ΣPAR sub-menu
The ΣPAR sub-menu contains functions used to modify statistical parameters.
The parameters shown correspond to the last example of data fitting.
The parameters shown in the display are:
Xcol: indicates column of ΣDATA representing x (Default: 1)
Ycol: indicates column of ΣDATA representing y (Default: 2)
Intercept: shows intercept of most recent data fitting (Default: 0)
Slope: shows slope of most recent data fitting (Default: 0)
Model: shows current data fit model (Default: LINFIT)
The functions listed in the soft menu keys operate as follows:
XCOL: entered as n @XCOL, changes Xcol to n.
YCOL: entered as n @YCOL, changes Ycol to n.

Table of Contents

Other manuals for HP 50G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 50G and is the answer not in the manual?

HP 50G Specifications

General IconGeneral
Digits33 digits
Battery typeCR2032
TypeScientific
Form factorPocket
Weight and Dimensions IconWeight and Dimensions
Weight220 g
Dimensions (WxDxH)87 x 184 x 23.5 mm

Related product manuals