23
Ste
Command
Remarks
2. Enter AUX line view
or class view.
• Enter AUX line view:
line aux first-number
[ last-number ]
• Enter AUX line class view:
line class aux
A setting in user line view is applied only to
the user line. A setting in user line class
view is applied to all user lines of the class.
A non-default setting in either view takes
precedence over a default setting in the
other view. A non-default setting in user
line view takes precedence over a
non-default setting in user line class view.
A setting in user line view takes effect
immediately and affects the online user. A
setting in user line class view does not
affect online users and takes effect only for
users who log in after the configuration is
completed.
3. Set the baud rate.
speed speed-value
By default, the baud rate is 9600 bps.
This command is not available in AUX line
class view.
4. Specify the parity
check mode.
parity { even | mark | none | odd |
space }
By default, the parity check mode is none,
and no parity check is performed.
This command is not available in AUX line
class view.
5. Specify the number
of stop bits.
stopbits { 1 | 1.5 | 2 }
The default is 1.
Stop bits indicate the end of a character.
The more the stop bits, the slower the
transmission.
This command is not available in AUX line
class view.
6. Specify the number
of data bits for
each character.
databits { 5 | 6 | 7 | 8 }
The default is 8.
The setting varies by character coding
type. For example, you can set it to 7 if
standard ASCII characters are to be sent. If
extended ASCII characters are to be sent,
set it to 8.
This command is not available in AUX line
class view.
7. Define a shortcut
key for starting a
terminal session.
activation-key character
By default, pressing Enter starts the
terminal session.
8. Define a shortcut
key for terminating
tasks.
escape-key { character | default }
By default, pressing Ctrl+C terminates a
task.
9. Configure the flow
control mode.
flow-control { hardware | none |
software }
This command is not available in AUX line
class view.
By default, the flow control mode is none.