122
Setting the port status detection timer
The device starts a port status detection timer when a port is shut down by a protocol. Once the detection
timer expires, the device brings up the port so the port status reflects the port's physical status.
To set the port status detection timer:
Step Command Remarks
1. Enter system view.
system-view N/A
2. Set the port status detection
timer.
shutdown-interval time The default setting is 30 seconds.
Configuring CPU usage monitoring
You can enable CPU usage monitoring so the system periodically samples and saves CPU usage. To
examine recent CPU usage, use the display cpu-usage history command.
You can also set CPU usage thresholds. When a CPU usage threshold is reached, the device sends a
trap.
To configure CPU usage monitoring:
Step Command Remarks
1. Enter system view.
system-view N/A
2. Enable CPU usage
monitoring.
monitor cpu-usage enable [ slot
slot-number [ cpu cpu-number ] ]
By default, CPU usage monitoring
is enabled.
3. Set the CPU usage sampling
interval.
monitor cpu-usage interval
interval-value [ slot slot-number
[ cpu cpu-number ] ]
By default, the CPU usage
sampling interval is 1 minute.
4. Set CPU usage thresholds.
monitor cpu-usage threshold
cpu-threshold [ slot slot-number
[ cpu cpu-number ] ]
By default, the CPU usage
threshold is 99%.
Setting memory thresholds
To ensure correct operation and improve memory utilization, the system monitors the memory usage and
the amount of free memory space in real time:
If the memory usage threshold is exceeded, the system generates and sends a trap.
If a free-memory threshold is exceeded, the system generates an alarm notification or an
alarm-removed notification and sends it to affected service modules or processes.
The device supports the following free-memory thresholds:
{ Normal state threshold.
{ Minor alarm threshold.
{ Severe alarm threshold.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 5130 EI series and is the answer not in the manual?

HP 5130 EI series Specifications

General IconGeneral
LayerLayer 3
VLANs4094
Multicast ProtocolsIGMP, PIM
Operating Temperature0°C to 45°C
ModelHP 5130 EI
Ports24 or 48 10/100/1000 ports
Uplink Ports4 x 1/10G SFP+
StackingUp to 9 switches
Power over Ethernet (PoE)PoE+ (IEEE 802.3at) on PoE+ models (JG936A, JG937A)
ManagementWeb, CLI, SNMP
MAC Address Table Size32, 000 entries
Routing ProtocolsOSPF, RIP, BGP, static routing
Operating Humidity10% to 90% (non-condensing)