22
The next time you log in through the console port, you must provide the configured login password.
Configuring scheme authentication for console login
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Enter AUX line view or
class view.
Enter AUX line view:
line aux first-number
[ last-number ]
Enter AUX line class view:
line class aux
A setting in user line view is applied only
to the user line. A setting in user line class
view is applied to all user lines of the
class.
A non-default setting in either view takes
precedence over a default setting in the
other view. A non-default setting in user
line view takes precedence over a
non-default setting in user line class view.
A setting in user line view takes effect
immediately and affects the online user.
A setting in user line class view does not
affect online users and takes effect only
for users who log in after the
configuration is completed.
3. Enable scheme
authentication.
authentication-mode scheme
By default, authentication is disabled for
the AUX line.
To use scheme authentication, you must also complete the following tasks:
Configure login authentication methods in ISP domain view.
To use remote authentication, configure the scheme to be used.
To use local authentication, configure a local user and the relevant attributes.
For more information, see Security Configuration Guide.
The next time you log in through the console port, you must provide the configured login username and
password.
Configuring common AUX line settings
Some common settings configured for an AUX line take effect immediately and can interrupt the current
session. Use a login method different from console login to log in to the device before you change AUX
line settings.
To log in through the console port after you configure AUX line settings, change the terminal settings on
the configuration terminal to match the line settings.
To configure common settings for an AUX line:
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 5130 EI series and is the answer not in the manual?

HP 5130 EI series Specifications

General IconGeneral
LayerLayer 3
VLANs4094
Multicast ProtocolsIGMP, PIM
Operating Temperature0°C to 45°C
ModelHP 5130 EI
Ports24 or 48 10/100/1000 ports
Uplink Ports4 x 1/10G SFP+
StackingUp to 9 switches
Power over Ethernet (PoE)PoE+ (IEEE 802.3at) on PoE+ models (JG936A, JG937A)
ManagementWeb, CLI, SNMP
MAC Address Table Size32, 000 entries
Routing ProtocolsOSPF, RIP, BGP, static routing
Operating Humidity10% to 90% (non-condensing)