Table
6.1
System Totals
Output
Voltages and Current
Startup (10 second)
Output Voltage Range Minimum Maximum Ripple (p-p)
+ 5 + 4.85
to
+ 5.25V
5.DA
18.3A
5Dmv
+ 12 + 11.4
to
+ 12.6V
D.DA
1.DA
12Dmv
+12M
+11.4to
13.2V 1.1A 5.5A
1DDmv
- 5 - 5.25
to
- 4.75
D.DA
D.25A
5Dmv
- 12 - 12.6
to
- 11.4
D.DA
D.25A 12Dmv
Total power: 176 watts maximum
After Startup
+ 5 + 4.85
to
+ 5.25V
5.DA
+
12
+ 11.4
to
+ 12.6V
D.DA
+12M
+11.4to
+12.6V
1.1A
- 5 - 5.25
to
- 4.75
D.DA
-
12
- 12.6
to
- 11.4
D.DA
Total power: 135 watts
Overvoltage Protection
17.5A
1.DA
2.4A
D.25A
D.25A
5Dmv
12Dmv
1DDmv
5Dmv
12Dmv
Overvoltage protection takes place within
SODus.
Afterwards, the
reset procedure
to
take
is:
unplug the system,
wait
for
five
minutes, plug
in
the system, then restart the system.
Overcurrent Protection
All outputs are protected (to ground
or
to
other outputs) against
short circuit. No damage shall result, however, the system will
require the reset procedure
as
given
in
the preceding paragraph.
76 Power Supply