Chapter 8 I/O Parameter
240
[110] IP Address (Parameter No.140)
No. Name Symbol Unit Input Range
Default factory
setting
140 IP Address IPAD
0.0.0.0 to
255.255.255.255
192.168.0.1
It is the parameter dedicated for Fieldbus (EtherNet/IP).
[For details, refer to Fieldbus Instruction Manual.]
[111] Subnet Mask (Parameter No.141)
No. Name Symbol Unit Input Range
Default factory
setting
141 Subnet Mask SNMK
0.0.0.0 to
255.255.255.255
255.255.255.0
It is the parameter dedicated for Fieldbus (EtherNet/IP).
[For details, refer to Fieldbus Instruction Manual.]
[112] Default Gateway (Parameter No.142)
No. Name Symbol Unit Input Range
Default factory
setting
142 Default Gateway DFGW
0.0.0.0 to
255.255.255.255
0.0.0.0
It is the parameter dedicated for Fieldbus (EtherNet/IP).
[For details, refer to Fieldbus Instruction Manual.]
[113] Overload Caution Load Level Ratio (Parameter No. 143)
No. Name Symbol Unit Input Range
Default factory
setting
143
overload caution load level
ratio
OLWL % 50 to 100 100
With the motor thrust increase temperature of when an overload caution warning gets
generated being set as 100%, the overload warning (message level) is output when the motor
temperature exceeds the rate set in this parameter.
The judgment would not be made if the value is set to 100%.
[114] Total Movement Count Threshold!(Parameter No.147)
No. Name Symbol Unit Input Range
Default factory
setting
147
Total Movement Count
Threshold
TMCT Times 0 to 999999999 0(Disabled)
An alarm is generated when the total movement count exceeds the value set to this parameter.
The judgment would not be made if the value is set to 0.
[115] Total Operated Distance Threshold (Parameter No.148)
No. Name Symbol Unit Input Range
Default factory
setting
148
Total Operated Distance
Threshold
ODOT m 0 to 999999999 0(Disabled)
An alarm is generated when the total operation distance exceeds the value set to this
parameter.
The judgment would not be made if the value is set to 0.