Table 4. Firmware Error Codes. (continued)
Error Code Description Action/
Possible Failing FRU
20D0 0A16 Error initializing interface/handling access
1. Check for system firmware updates. Apply
update if available.
2. Contact your next level of support for
assistance.
20D0 0A17 Error initializing interface/utility access
1. Check for system firmware updates. Apply
update if available.
2. Contact your next level of support for
assistance.
20D0 0A18 Error initializing register softpatch access
1. Check for system firmware updates. Apply
update if available.
2. Contact your next level of support for
assistance.
20D0 9001 Subsystem information not found in VPD
1. Power off, then power on the system.
2. If the error persists, call service support.
20D0 9002 Subsystem machine type and model
information not found in VPD
1. Power off, then power on the system.
2. If the error persists, call service support.
20D0 9003 Subsystem serial number information not found
in VPD
1. Power off, then power on the system.
2. If the error persists, call service support.
20D0 9004 Subsystem machine type and model field is
empty in VPD
1. Power off, then power on the system.
2. If the error persists, call service support.
20D0 9005 Subsystem serial number field is empty in VPD
1. Power off, then power on the system.
2. If the error persists, call service support.
20D0 9006 Duplicate subsystem serial number found in
VPD
1. Power off, then power on the system.
2. If the error persists, call service support.
20D0 9007 Invalid subsystem machine type and model
information in VPD
1. Power off, then power on the system.
2. If the error persists, call service support.
20D0 9008 Invalid subsystem serial number found in VPD
1. Power off, then power on the system.
2. If the error persists, call service support.
20D1 0001 Failed to send state-change message to service
processor
1. Check for system firmware updates. Apply
update if available.
2. Contact your next level of support for
assistance.
20D1 0002 Failed to disable heartbeat alarm
1. Check for system firmware updates. Apply
update if available.
2. Contact your next level of support for
assistance.
20D1 0003 Failed to send boot status
1. Check for system firmware updates. Apply
update if available.
2. Contact your next level of support for
assistance.
Chapter 5. Error Code to FRU Index 229

Table of Contents

Other manuals for IBM pSeries 630 6C4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM pSeries 630 6C4 and is the answer not in the manual?

IBM pSeries 630 6C4 Specifications

General IconGeneral
BrandIBM
ModelpSeries 630 6C4
CategoryServer
LanguageEnglish

Related product manuals