⢠Connect all power cords to a properly wired and grounded electrical outlet. Ensure that the
outlet supplies proper voltage and phase rotation according to the system rating plate.
⢠Connect any equipment that will be attached to this product to properly wired outlets.
⢠When possible, use one hand only to connect or disconnect signal cables.
⢠Never turn on any equipment when there is evidence of îłre, water, or structural damage.
⢠Disconnect the attached power cords, telecommunications systems, networks, and modems
before you open the device covers, unless instructed otherwise in the installation and
conîłguration procedures.
⢠Connect and disconnect cables as described in the following procedures when installing,
moving, or opening covers on this product or attached devices.
To disconnect:
1. Turn off everything (unless instructed otherwise).
2. Remove the power cords from the outlets.
3. Remove the signal cables from the connectors.
4. Remove all cables from the devices.
To connect:
1. Turn off everything (unless instructed otherwise).
2. Attach all cables to the devices.
3. Attach the signal cables to the connectors.
4. Attach the power cords to the outlets.
5. Turn on the devices.
⢠Sharp edges, corners and joints might be present in and around the system. Use care when
handling equipment to avoid cuts, scrapes and pinching. (D005)
DANGER:
Heavy equipmentâpersonal injury or equipment damage might result if mishandled.
(D006)
DANGER: DANGER: Serious injury or death can occur if loaded lift tool falls over or if a heavy load
falls off the lift tool. Always completely lower the lift tool load plate and properly secure the load
on the lift tool before moving or using the lift tool to lift or move an object. (D010)
DANGER: Observe the following precautions when working on or around your IT rack system:
⢠Heavy equipmentâpersonal injury or equipment damage might result if mishandled.
⢠Always lower the leveling pads on the rack cabinet.
⢠Always install stabilizer brackets on the rack cabinet.
⢠To avoid hazardous conditions due to uneven mechanical loading, always install the heaviest
devices in the bottom of the rack cabinet. Always install servers and optional devices starting
from the bottom of the rack cabinet.
⢠Rack-mounted devices are not to be used as shelves or work spaces. Do not place objects on top
of rack-mounted devices.
⢠Each rack cabinet might have more than one power cord. Be sure to disconnect all power cords
in the rack cabinet when directed to disconnect power during servicing.
⢠Connect all devices installed in a rack cabinet to power devices installed in the same rack
cabinet. Do not plug a power cord from a device installed in one rack cabinet into a power device
installed in a different rack cabinet.
⢠An electrical outlet that is not correctly wired could place hazardous voltage on the metal parts
of the system or the devices that attach to the system. It is the responsibility of the customer to
xxiv Storwize V7000 : Gen3 Quick Installation Guide for MTM 2076-724, 2076-U7B, 2076-12F, 2076-24F, and
2076-92F