Table C-1. Library Sense Data and associated ASC/ASCQs (continued)
Sense
Key ASC ASCQ Description Required Action
5 24h 00h Invalid field in CDB An invalid value was detected in the
Command Descriptor Block.
Failure Isolation Procedure
See “Contacting IBM Technical Support” on
page 9-15.
5 25h 00h Illegal LUN The command was addressed to a
non-existent Logical Unit Number.
Failure Isolation Procedure
See “Contacting IBM Technical Support” on
page 9-15.
5 26h 00h Invalid field in Parameter List An invalid value was detected in the data
sent during the data phase.
Failure Isolation Procedure
See “Contacting IBM Technical Support” on
page 9-15.
5 26h 04h Invalid release of persistent reservation
6 28h 00h Door(s) opened and closed A cartridge has been loaded successfully
into the drive and is now ready to be
accessed.
6 28h 01h I/O station opened and closed **The I/O Station was opened and closed
since the last time the initiator last accessed
it.
6 29h 00h Power on or reset occurred Reset. The drive has powered on or
received a reset since the initiator last
accessed it.
Failure Isolation Procedure
No action is necessary. these are only
status messages.
6 29h 01h Power on occurred Reset. The drive has powered on or
received a reset since the initiator last
accessed it.
Failure Isolation Procedure
No action is necessary. these are only
status messages.
6 29h 04h Internal reset occurred Status changed.
Failure Isolation Procedure
No action is necessary. These are only
status messages.
C-4 TS3310 Tape Library Setup and Operator Guide