EasyManuals Logo

IBM System Storage TS3310 User Manual

IBM System Storage TS3310
275 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #249 background imageLoading...
Page #249 background image
Table C-2. LTO Tape Drive Sense Data (continued)
Byte
Bit Address or Name
7 6 5 4 3 2 1 0
12–13
Additional Sense Code (ASC)
Additional Sense Code Qualifier (ASCQ)
Byte 12 Byte 13
ASC ASCQ
00 00 - No additional sense The flags in the sense data indicate the reason for
the command failure
00 01 - Filemark detected A Read or Space command terminated early due to an FM
The FM flag is set.
00 02 - EOM A Write or Write File Marks command failed because the physical
end of tape was encountered, or a Read or Space command encountered EOM
The EOM flag is set
00 04 - BOM A space command ended at Beginning of Tape
The EOM bit is also set
00 05 - EOD Read or Space command terminated early
because End of Data was encountered
00 16 - Operation in progress
04 00 - Cause not reportable A cartridge is present in the drive, but it is in the
process of being unloaded
04 01 - Becoming Ready A media access command was received during a
front panel initiated load or an immediate reported load command
04 02 - Initializing Command Required A cartridge is present in the drive, but is not
logically loaded. A Load command is required
04 03 - Manual Intervention Required A cartridge is present in the drive but could
not be loaded or unloaded without manual intervention
04 12 - Logical Unit Not Ready, Offline
08 01 - Logical Unit Communication Failure
09 00 - Track Following Error (Servo)
0C 00 - Write Error A Write operation has failed. This is probably due to bad
media, but may be hardware related
11 00 - Unrecovered Read Error A Read operation failed. This is probably due
to bad media, but may be hardware related
14 00 - Recorded Entity Not Found A space or Locate command failed because
a format violation prevented the target from being found.
14 03 - End Of Data not found A Read type operation failed because a format
violation related to a missing EOD data set
17 01 - Recovered Data with Retries
1A 00 - Parameter list length error The amount of parameter data sent is incorrect
20 00 - Invalid Command Operation Code The Operation Code in the command
was not a valid Operation Code
24 00 - Invalid field in CDB An invalid field has been detected in a
Command Descriptor Block
25 00 - LUN not supported The command was addressed to a non-existent
logical unit number
26 00 - Invalid Field in Parameter List An invalid field has been detected in the
data sent during the data phase
27 00 - Write Protect A Write type operation has been requested on a cartridge which
has been write protected
28 00 - Not Ready to Ready Transition A cartridge has been loaded successfully into
the drive and is now ready to be accessed
28 01 - Import or Export Element Accessed
29 00 - Reset The drive has powered on, received a reset signal or a bus device
reset signal since the initiator last accessed it
29 04 - Device Internal Reset
(Continued on next page)
Appendix C. Sense Data C-9

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System Storage TS3310 and is the answer not in the manual?

IBM System Storage TS3310 Specifications

General IconGeneral
ModelTS3310
TypeTape Library
Power SupplyDual redundant power supplies
Tape TechnologyLTO (Linear Tape-Open)
Humidity20% to 80% non-condensing

Related product manuals