EasyManuals Logo

IBM System x3650 M5 User Manual

IBM System x3650 M5
1010 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #413 background imageLoading...
Page #413 background image
80070101-2c01ffff Sensor [SensorElementName] has transitioned from normal to non-critical state. (ML2
OverTemp)
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to
non-critical from normal.
May also be shown as 800701012c01ffff or 0x800701012c01ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0520
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server),
that the air baffle is in place and correctly installed, and that the server cover is installed and completely closed.
2. Check the ambient temperature. You must be operating within the specifications (see Server Features and
specifications for more information).
3. Replace the failed ML2 card.
8007010d-2582ffff Sensor [SensorElementName] has transitioned from normal to non-critical state. (RAID Vol
State)
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to
non-critical from normal.
May also be shown as 8007010d2582ffff or 0x8007010d2582ffff
Severity: Warning
Alert Category: Warning - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0520
SNMP Trap ID: 60
Automatically notify Support: No
User response:
1. Run the hard disk drive diagnostic test on drive n.
2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b.
Cable from the system board to the backplane
3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard
disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive
number)
80070101-2c01ffff 8007010d-2582ffff
Appendix A. Integrated management module II (IMM2) error messages 397

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3650 M5 and is the answer not in the manual?

IBM System x3650 M5 Specifications

General IconGeneral
Processor CoresUp to 22 cores per processor
Memory Slots24 DIMM slots
Form Factor2U rack server
ProcessorIntel Xeon E5-2600 v3/v4
MemoryUp to 1.5 TB (24x 64 GB LRDIMMs)
RAID SupportRAID 0, 1, 5, 6, 10, 50, 60
Network4x 1 GbE ports standard, optional 10 GbE
Power SupplyUp to 2x redundant hot-swap 550W, 750W, or 900W power supplies
Operating System SupportWindows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware
ManagementIntegrated Management Module (IMM) v2.1
StorageUp to 24 x 2.5" or 12 x 3.5" drives

Related product manuals