S.3050007 [S.3050007]
Explanation: A firmware fault has been detected in the UEFI image. Internal UEFI Firmware Fault Detected, System
halted
Severity: Error
User response: Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
2. Update the UEFI image.
3. Replace the system board.
S.3058004 [S.3058004]
Explanation: A Three Strike boot failure has occurred. The system has booted with default UEFI settings. POST
failure has occurred! System booted with default settings.
Severity: Error
User response: Complete the following steps:
1. This event resets UEFI to the default settings for the next boot. If successful, the Setup Utility is displayed. The
original UEFI settings are still present.
2. If you did not intentionally trigger the reboots, check logs for probable cause.
3. Undo recent system changes (settings or devices added). If there were no recent system changes, remove all
options, and then remove the CMOS battery for 30 seconds to clear CMOS contents. Verify that the system boots.
Then, re-install the options one at a time to locate the problem.
4. Check the IBM support site for an applicable service bulletin or firmware update that applies to this error.
5. Update the UEFI firmware.
6. Remove and re-install CMOS battery for 30 seconds to clear CMOS contents.
7. (Trained service technician only) Replace the system board.
S.3060007 [S.3060007]
Explanation: A firmware fault has been detected in the UEFI image. Internal UEFI Firmware Fault Detected, System
halted
Severity: Error
User response: Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
2. Update the UEFI image.
3. Replace the system board.
S.3050007 S.3060007
826
System x3650 M5 Type 5462: Installation and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3650 M5 and is the answer not in the manual?

IBM System x3650 M5 Specifications

General IconGeneral
Processor CoresUp to 22 cores per processor
Memory Slots24 DIMM slots
Form Factor2U rack server
ProcessorIntel Xeon E5-2600 v3/v4
MemoryUp to 1.5 TB (24x 64 GB LRDIMMs)
RAID SupportRAID 0, 1, 5, 6, 10, 50, 60
Network4x 1 GbE ports standard, optional 10 GbE
Power SupplyUp to 2x redundant hot-swap 550W, 750W, or 900W power supplies
Operating System SupportWindows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware
ManagementIntegrated Management Module (IMM) v2.1
StorageUp to 24 x 2.5" or 12 x 3.5" drives

Related product manuals