Table 7. Integrated management module error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, “Parts listing, Type 7377 server,” on page 125 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Message Severity Description Action
Security: Login ID: '%1' had
%2 login failures from CLI at
%3. (%1 = user ID; %2 =
MaximumSuccessiveLogin
Failures (currently set to 5 in
the firmware);
%3 = IP address,
xxx.xxx.xxx.xxx)
Error A user has exceeded the maximum
number of unsuccessful login
attempts from the command-line
interface and has been prevented
from logging in for the lockout
period.
1. Make sure that the correct login
ID and password are being
used.
2. Have the system administrator
reset the login ID or password.
Security: Userid: '%1' had
%2 login failures from WEB
client at IP address %3.
(%1 = user ID;
%2 =
MaximumSuccessiveLogin
Failures (currently set to 5 in
the firmware);
%3 = IP address,
xxx.xxx.xxx.xxx)
Error A user has exceeded the maximum
number of unsuccessful login
attempts from a Web browser and
has been prevented from logging in
for the lockout period.
1. Make sure that the correct login
ID and password are being
used.
2. Have the system administrator
reset the login ID or password.
Sensor CPU n OverTemp
has transitioned to critical
from a less severe state.
(n = microprocessor number)
Error A sensor has changed to Critical
state from a less severe state.
1. Make sure that the fans are
operating, that there are no
obstructions to the airflow, that
the air baffle is in place and
correctly installed, and that the
server cover is installed and
completely closed.
2. Make sure that the heat sink for
microprocessor n is installed
correctly.
3. (Trained service technician only)
Replace microprocessor n.
(n = microprocessor number)
Sensor CPU n OverTemp
has transitioned to
non-recoverable from a less
severe state.
(n = microprocessor number)
Error A sensor has changed to
Nonrecoverable state from a less
severe state.
1. Make sure that the fans are
operating, that there are no
obstructions to the airflow, that
the air baffle is in place and
correctly installed, and that the
server cover is installed and
completely closed.
2. Make sure that the heat sink for
microprocessor n is installed
correctly.
3. (Trained service technician only)
Replace microprocessor n.
(n = microprocessor number)
Chapter 3. Diagnostics 113

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM x3630 M3 7377 and is the answer not in the manual?

IBM x3630 M3 7377 Specifications

General IconGeneral
Product FamilySystem x
Machine Type7377
Max Processors2
ChipsetIntel 5520
Memory Slots12 DIMM slots
ProcessorIntel Xeon 5600 series
MemoryUp to 192 GB
RAID SupportRAID 0, 1, 10, 5, 50
Network Interface2 x Gigabit Ethernet
Power SupplyHot-swap, redundant
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware