Table 7. Integrated management module error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, “Parts listing, Type 7377 server,” on page 125 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Message Severity Description Action
Sensor DIMM n Temp has
transitioned to critical from a
less severe state.
(n = DIMM number)
Error A sensor has changed to Critical
state from a less severe state.
1. Make sure that the fans are
operating, that there are no
obstructions to the airflow, that
the air baffle is in place and
correctly installed, and that the
server cover is installed and
completely closed.
2. If a fan has failed, complete the
action for a fan failure.
3. Replace DIMM n.
(n = DIMM number)
Sensor PS n Fan Fault has
transitioned to critical from a
less severe state.
(n = PS number)
Error A sensor has changed to Critical
state from a less severe state.
Replace the corresponding power
supply.
SSL data in the IMM
configuration data is invalid.
Clearing configuration data
region and disabling
SSL+H25.
Error There is a problem with the
certificate that has been imported
into the IMM. The imported
certificate must contain a public key
that corresponds to the key pair
that was previously generated
through the Generate a New Key
and Certificate Signing Request
link.
1. Make sure that the certificate
that you are importing is
correct.
2. Try to import the certificate
again.
The Chassis Event Log
(CEL) on system %1 cleared
by user %2. (%1 =
CIM_ComputerSystem.
ElementName;
%2 = user ID)
Info A user has cleared the IMM event
log.
No action; information only.
The Chassis Event Log
(CEL) on system %1 is
100% full. (%1 =
CIM_ComputerSystem.
ElementName)
Info The IMM event log is full. When the
log is full, older log entries are
replaced by newer ones.
To avoid losing older log entries,
save the log as a text file and clear
the log.
The Chassis Event Log
(CEL) on system %1 is 75%
full. (%1 =
CIM_ComputerSystem.
ElementName)
Info The IMM event log is 75% full.
When the log is full, older log
entries are replaced by newer ones.
To avoid losing older log entries,
save the log as a text file and clear
the log.
114 IBM System x3630 M3 Type 7377: Problem Determination and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM x3630 M3 7377 and is the answer not in the manual?

IBM x3630 M3 7377 Specifications

General IconGeneral
Product FamilySystem x
Machine Type7377
Max Processors2
ChipsetIntel 5520
Memory Slots12 DIMM slots
ProcessorIntel Xeon 5600 series
MemoryUp to 192 GB
RAID SupportRAID 0, 1, 10, 5, 50
Network Interface2 x Gigabit Ethernet
Power SupplyHot-swap, redundant
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware