Intermec EasyCoder 501 E – Installation & Operation Ed. 1 53
Chapter 7 Setting Up the Printer
Default Setup
The printers default
setup with standard con guration EPROMs
is listed below:
Contrast
Middle (5)
Ser-Com ("uart1:")
Baud rate: 9600
Parity: none
Character length: 7 bits
Stop bits: 2 bits
RTS/CTS: Disable
ENQ/ACK: Disable
XON/XOFF, data to host: Enable
XON/XOFF, data from host: Enable
New line: CR/LF
Detection
Feedadjust:
Startadjust: 0
Stopadjust: 0
Service
Media Size:
X-start (8 /11.81 dots per mm): 0/0
Width (8 /11.81 dots per mm): 832/1280
Length (8 /11.81 dots per mm): 1200/1200
Media type: Label (w Gaps)
Print defs:
Paper type (thermal transfer printers): UBI HP 20
Paper type (direct thermal printers): RICOH 130LAB/LAM
Performance: Normal
Memory alloc:
Image buffer size: 48 Kbytes
Receive buffer: 300 bytes
Transmit buffer: 300 bytes
The printers current setup values can be read from the printers
display window by browsing through the Setup Mode, or from the
host by browsing through the Terminal Setup of Intermec Shell.
You can list the printers current setup values by printing test label
#5 in the Setup Mode or by using Intermec Shell. The current setup
values can be sent to the host via the standard serial communication
channel using a SETUP WRITE "uart1:" statement (see Intermec
Fingerprint v6.14, Reference Manual).
Reading the
Current Setup

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec EasyCoder 501 E and is the answer not in the manual?

Intermec EasyCoder 501 E Specifications

General IconGeneral
BrandIntermec
ModelEasyCoder 501 E
CategoryLabel Maker
LanguageEnglish

Related product manuals