Intermec EasyCoder 501 E – Installation & Operation Ed. 1 85
Chapter 9 Intermec Shell Startup Program
Terminal Setup, cont.
Changing the Setup
To set up the printer or use any other of the facilities, answer N
(No) to the Select Application prompt. The following example
illustrates how to change the printers communication setup from
19,200 baud to 9,600 baud on "uart1:".
----------------
SHELL
SEL. APPLICATION
----------------
(Y / N / B):N
----------------
SHELL
SETUP
----------------
(Y / N / B):Y
----------------
SETUP FROM
TERMINAL
----------------
Reading printer setup, please wait.
If no change, press ENTER
To end terminal setup: enter QUIT (Q), or QUIT and SAVE (S)
CONTRAST,5
New value: (0-10) :
UART1,BAUDRATE,19200
New value: (1:300 2:600 3:1200 4:2400 5:4800 6:9600 7:19200) :6
Comment: You must specify the baud rate by a digit (1-7) according
to the displayed list of options and then press enter.
UART1,PARITY,NONE
New value: (1:NONE 2:EVEN 3:ODD 4:MARK 5:SPACE) :S
Comment: Enter Q to quit without saving, or S to save the new
setup and quit the Terminal Setup.
Are you sure? (Y / N):Y