EasyManuals Logo

Intermec EasyCoder 501 E User Manual

Intermec EasyCoder 501 E
151 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #86 background imageLoading...
Page #86 background image
Intermec EasyCoder 501 E – Installation & Operation Ed. 1 85
Chapter 9 Intermec Shell Startup Program
Terminal Setup, cont.
Changing the Setup
To set up the printer or use any other of the facilities, answer N
(No) to the Select Application prompt. The following example
illustrates how to change the printers communication setup from
19,200 baud to 9,600 baud on "uart1:".
----------------
SHELL
SEL. APPLICATION
----------------
(Y / N / B):N
----------------
SHELL
SETUP
----------------
(Y / N / B):Y
----------------
SETUP FROM
TERMINAL
----------------
Reading printer setup, please wait.
If no change, press ENTER
To end terminal setup: enter QUIT (Q), or QUIT and SAVE (S)
CONTRAST,5
New value: (0-10) :
UART1,BAUDRATE,19200
New value: (1:300 2:600 3:1200 4:2400 5:4800 6:9600 7:19200) :6
Comment: You must specify the baud rate by a digit (1-7) according
to the displayed list of options and then press enter.
UART1,PARITY,NONE
New value: (1:NONE 2:EVEN 3:ODD 4:MARK 5:SPACE) :S
Comment: Enter Q to quit without saving, or S to save the new
setup and quit the Terminal Setup.
Are you sure? (Y / N):Y
xf~xxff`xx~f`ffffffffffffffffffffxxxf`ff`ffffffffffffffffffffffffxx~fx
Comment: Since you have changed the communication parameters,
the messages from the printer will become garbled. Change the
terminals setup so it matches the printers and press Enter.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec EasyCoder 501 E and is the answer not in the manual?

Intermec EasyCoder 501 E Specifications

General IconGeneral
BrandIntermec
ModelEasyCoder 501 E
CategoryLabel Maker
LanguageEnglish

Related product manuals