EasyManuals Logo

Intermec EasyCoder 501 E User Manual

Intermec EasyCoder 501 E
151 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #56 background imageLoading...
Page #56 background image
Intermec EasyCoder 501 E – Installation & Operation Ed. 1 55
Chapter 7 Setting Up the Printer
Setup Parameters, cont.
Serial Communication,
cont.
Parity
The parity decides how the rmware will check for transmission
errors. There are ve options:
None (default)
Even
Odd
Mark
Space
Character Length
The character length speci es the number of bits that will de ne a
character. Eight bits allows more special characters and characters
specific for foreign laguages to be used. Refer to the Intermec
Fingerprint v6.14, Reference Manual for information on which
characters are available in various combinations of character length
and character set.
7 Characters ASCII 000 to 127 decimal (default)
8 Characters ASCII 000 to 255 decimal
Stop Bits
The number of stop bits speci es how many bits will de ne the end
of a character. There are two options:
1
2 (default)
Flow Control
There are several ways to control the exchange of data (handshak-
ing) between the printer and the connected computer or other
device. Each option can be enabled or disabled separately, but
normally only one alternative should be enabled. For galvanically
insulated interfaces (that is, 20 mA current loop and RS-422),
ENQ/ACK or XON/XOFF are to prefer in order to retain interference
protection and to limit the number of lines.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec EasyCoder 501 E and is the answer not in the manual?

Intermec EasyCoder 501 E Specifications

General IconGeneral
BrandIntermec
ModelEasyCoder 501 E
CategoryLabel Maker
LanguageEnglish

Related product manuals