Intermec EasyCoder 501 E – Installation & Operation Ed. 182
Chapter 9 Intermec Shell Startup Program
The Terminal Setup program in Intermec Shell allows the operator
to control the whole Intermec Shell program remotely from a host
computer or terminal and to read or change the printers setup. There
must be a working two-way (serial) communication between printer
and host, and the host must be running a suitable communication
program (for example MS Windows HyperTerminal) that can
transmit and receive data in ASCII format; that is, as printable
characters. Set up the terminal as VT100.
Enter Terminal Setup by transmitting three upper- or lowercase T
characters (TTT or ttt) while the printer either shows the Intermec
Shell countdown menus or the Select Application menu.
If you cannot start Terminal Setup, the communication protocols
of the printer and the host probably do not match, or there is some
other communication error. For example, you may have a defective
communication cable, the wrong port may be selected on the host, or
the cable is not connected to "uart1:" on the printer
1
.
You can check and change the printers setup in the Setup Mode,
which you can enter by pressing the <Setup> key on the printers
built-in keyboard. Proceed as described in Chapter 8, Setup Mode.
Among the facilities in Intermec Shell, you will also nd a number
of options that allow you to read or change the communication
setup of the printer:
Setup
This is another way of entering the Setup Mode, where you
can browse through the setup parameters and make changes
using the printers keyboard.
Print Setup
Here you can print the current setup on one or more labels.
Ser-Com Reset
This option allows you to reset the communication parameters
for all serial communication channels on the printer to default
values.
Change the communication setup of the printer according to the
host or vice versa.
Once printer and host have been set up with the same communication
parameters, go to the Select Application menu and use the triple
T (TTT or ttt) to start Terminal Setup.
Terminal Setup
Starting Terminal Setup
Solving Communication
Problems
1
/. By default, "uart1:" is standard
IN/OUT channel and should be
used for running Terminal Setup.
However, other ports could be
appointed standard IN and/or
OUT channel using the Intermec
Fingerprint statement SETSTDIO.
Refer to the Intermec Fingerprint
manuals for further information.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec EasyCoder 501 E and is the answer not in the manual?

Intermec EasyCoder 501 E Specifications

General IconGeneral
BrandIntermec
ModelEasyCoder 501 E
CategoryLabel Maker
LanguageEnglish

Related product manuals