Chapter 4 — ESim Commands
ESim for the PC4 and PF8 Printers Programmer’s Reference Manual 37
Remarks: The “DATA” field can be replaced by or combined with the commands
below:
Example 1: The command Cn±x in this example is used twice to
increment the single counter by one (1) in each position (last two A-
command lines).
Set the Form Step Value p4 to +3 for the counter Cn used in our
example (see the C-command line) and refer to the C-Counter
command.
FK”TEST2”
FS”TEST2”
C0,5,L,+3,“Counter 0”
A180,50,0,3,1,1,N,C0
A380,50,0,3,1,1,N,C0+1
A580,50,0,3,1,1,N,C0+2
FE
Note: Font size 5 only supports uppercase characters, see
example 5 in the label above.
DATA Field Command Descriptions
Command Description
Variable:
Vnn Prints the contents of the variable “nn” at this
position, where n is a 2 digit number from 00-
99.
Consecutive
number counter:
Cn
Cn±x
Prints the value of counter “n” at this
position.
Prints the value of counter “n” at this position
while setting the counters start value to “x”. n
and x are 1 digit numbers from 0-9.
Enter + to increase the value or - to decrease
the value.

Table of Contents