Chapter 4 — ESim Commands
48 ESim for the PC4 and PF8 Printers Programmer’s Reference Manual
Y Bar height on two-dimensional composite part
in dots. Minimum height is 2*x, nominal is 4*x.
Limit is 2-999. Default is 4 (2*x).
s Separator pattern height in dots between linear
component and two dimensional composite
component. Limits is 1-60 (minimum s = 1*x,
maximum s = 6*x). Default is same as x.
l Manually controlled column count on CC-C
code. If not set, the column count is optimized
to linear bar width. Limit is 1-30. Default is NA.
B Flag for human readable text of linear
component part, to present within the same
rules as to the single bar code. Font selection
depends on the bar code type. It is similar to B-
command parameter p
8
, see “B - Standard Bar
Codes” on page 40.
Default is no B flag.
px, y, m Human readable text of two-dimensional
composite component part appended by
additional variables for any position relocation
around the composite bar code:
x = horizontal start location: max is 4 digits.
y = vertical start location: max is 4 digits.
m = maximum characters per line. The max is 3
digits, and 0 = no limit.
Fixed Font selection 3 without any multiplier
used.
CR, LF in data causes the rest of the text to wrap
around to the next line.
Similar design as b-command parameter p on
PDF417.
Limits are x and y position limitations.
Default is no p.
b - EAN/UCC Command Parameter Description (continued)
Parameter Description