6. Operating settings data decoding security
130
ScanPlus 1800 - Installation Manual
consecutive same read data validation
- data is only transmitted after repeated reads give the same result
single read before transmission (*)
\45\4B\01\60
compose number of same reads: [range: 0-10]
\45\4B\60
- enter a number string and scan End Selection
(Appendix C)
timeout between identical consecutive codes
- prevents reading the same bar code more than once
300 ms (*)
\45\4C\04\2C\60
compose (ms):
\45\4C\60
- enter a number string and scan End Selection
(Appendix C)