4. Data transmission settings keyboard wedge
ScanPlus 1800 - Installation Manual
41
special keys transmission
- only symbologies that support the full ASCII character set allow the encoding of special
keyboard keys such as <Return> and <Tab>
- no symbologies support the encoding of other function keys such as <PF1> and <PageDown>
- the special keys transmission codes allow you to transmit special keyboard keys as a single
keyboard character, a [<Ctrl> + character] combination, or an [<Alt> + decimal_sequence]
combination
control character conversion
- emulates PC AT keyboard [<Ctrl> + character] sequence or transmits certain keyboard
functions directly as single keyboard characters
on (*)
\47\4D\60
- transmits the following characters directly as
single keyboard characters:
ASCII character: transmitted as:
8 <Backspace> (not <Ctrl> H )
9 <Tab> (not <Ctrl> I )
10 (not transmitted)
13 <Enter> (not <Ctrl> M )
27 <Escape> (not <Ctrl> [ )
- useful to avoid confusion for applications that
already use control sequences as commands

Table of Contents

Other manuals for Intermec ScanPlus 1800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec ScanPlus 1800 and is the answer not in the manual?

Intermec ScanPlus 1800 Specifications

General IconGeneral
BrandIntermec
ModelScanPlus 1800
CategoryBarcode Reader
LanguageEnglish

Related product manuals