EasyManua.ls Logo

Intermec ScanPlus 1800 - Wand Emulation; Margin Size; Transmitted Symbology Type

Intermec ScanPlus 1800
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4. Data transmission settings wand emulation
66
ScanPlus 1800 - Installation Manual
wand emulation
- default values (*) are for analog wand emulation
- transmitted symbology type :
- PDF417, Telepen : data is transmitted in Code 128 format
- all other symbologies : data can be transmitted in original barcode format or in Code 39
format
transmitted symbology type
- transmits data in original barcode format or in Code 39 format
transmission in original code format (*)
\5E\00\60
transmission in Code 39
\5E\01\60
- original code must not contain characters not
supported by Code 39
margin size
- defined in increments of narrow bar width (50 µs)
10 x narrow bar width (*)
\5A\0A\60