EasyManuals Logo

Intermec ScanPlus 1800 Installation Manual

Intermec ScanPlus 1800
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
4. Data transmission settings RS-232
ScanPlus 1800 - Installation Manual
49
ENQ
- ENQ not used: barcode data is transmitted without receiving a request from the host system
- ENQ used: data is transmitted if ENQ character received from host system before end of
hardware/software protocols time-out
not used (*)
\47\3E\00\60
used (ENQ 05h)
\47\3E\05\60
compose:
\47\60
- enter an ASCII character and scan End
Selection (Appendix A)
ACK
- activating ACK or NAK activates the ACK/NAK protocol
- before reading a new bar code after transmission, the product waits for an ACK (positive
acknowledge) from the host system or until the end of the hardware/software protocols time-out
not used (*)
\48\3E\00\60
used (ACK 06h)
\48\3E\06\60

Table of Contents