7. Configuration modes and utilities
ScanPlus 1800 - Installation Manual
137
7. Configuration modes and utilities
configuration enable (*)
\46\50\60
- configuration possible all the time
configuration inhibit after 1 mn
\46\51\60
- protects the product against unwanted
configuration
- configuration only possible before end of 1
minute timeout (cycle repeated until no config
code read within 1 minute)
configuration inhibit
1 mn
1 mn
configuration code
configuration codeScanPlus startup
1 mn
transparent configuration mode
\46\41\03\60
- allows you to use your barcode reader to set up
other products (setup commands are
transmitted to the other product but do not
affect your reader)
- remains active until you switch off the product