3. Terminal / cash register used in your application predefined terminal selections
ScanPlus 1800 - Installation Manual
25
analog wand emulation (Intermec Interface, white high)
\41\4A\02\07\60
- bar = 0, space = 1, margin = 1, quiet zone = 1
- energy saver mode, active while trigger pressed,
standby after good read (see section 6,
"Operating settings - trigger activation")
- beeps not active, good read LED before
transmission, pulse duration = 0.15 ms, no
intermessage delay
- for Intermec products such as 97XX wedge
products, JANUS 2010 hand-held computers,
TRAKKER Antares 242X terminals, use :
ScanPlus 1800 product P/N
ScanPlus 1800 SR + wand emulation cable 0 - 3 6 0 0 5 1 - 0 1
ScanPlus 1800 ST + wand emulation cable 0 - 3 6 6 0 5 1 - 0 1
wand emulation cable 0 - 3 6 6 0 3 1 - 0 0
digital wand emulation (black high)
\41\4A\02\02\60
- bar = 1, space = 0, margin = 0, quiet zone = 0
- good read beeps after transmission, pulse
duration = 0.85 ms, intermessage delay = 750
ms