Goodrive200 inverters Function codes
127
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
of
communic
ation
overtime
When the function code is set as 0.0, the
communication overtime parameter is invalid.
When the function code is set as non-zero, if the
interval time between two communications
exceeds the communication overtime, the
system will report “485 communication faults”
(CE).
Generally, set it as invalid; set the parameter in
the continuous communication to monitor the
communication state.
P14.05
Transmissi
on fault
processing
0:Alarm and stop freely
1:No alarm and continue to run
2:No alarm and stop according to the stop means
(only under the communication control)
3:No alarm and stop according to the stop means
(under all control modes)
0
P14.06
Communic
ation
processing
LED ones:
0: Operation with response: the drive will respond
to all reading and writing commands of the upper
monitor.
1:Operation without responseThe drive only
responds to the reading command other than the
writing command of the drive. The
communication efficiency can be increased by
this method.
LED tens:
0: Communication encrypting valid
1: Communication encrypting invalid
0x00
P14.07
Reserved
P14.08
R
eserved
P15 Group Reserved

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT GD200-037G/045P-4 and is the answer not in the manual?

INVT GD200-037G/045P-4 Specifications

General IconGeneral
BrandINVT
ModelGD200-037G/045P-4
CategoryInverter
LanguageEnglish

Related product manuals