Goodrive200 inverters Fault tracking
204
F
ault code
Fault type Possible cause What to do
PIDE PID feedback fault
PID feedback offline
PID feedback source
disappear
Check the PID feedback
signal
Check the PID feedback
source
bCE Braking unit fault
Braking circuit fault or
damage to the braking
pipes
The external braking
resistor is not sufficient
Check the braking unit and
change new braking pipe
Increase the braking
resistor
ETH1
Grounding
shortcut fault 1
The output of the inverter
is short circuited with the
ground
There is fault in the current
detection circuit
The actual motor power
sharply differs from the
inverter power
Check if the connection of
the motor is normal or not
Change the hoare
Change the main control
panel
Set motor parameters
correctly
ETH2
Grounding
shortcut fault 2
The output of the inverter
is short circuited with the
ground
There is fault in the current
detection circuit
The actual motor power
sharply differs from the
inverter power
Check if the connection of
the motor is normal or not
Change the hoare
Change the main control
panel
Set motor parameters
correctly
dEu
Velocity deviation
fault
The load is too heavy or
stalled
Check the load and
ensure it is normal
Increase the detection
time
Check whether the control
parameters are normal

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT GD200-037G/045P-4 and is the answer not in the manual?