System Commands
Copyright© Itech Electronic Co., Ltd. 11
Query syntax
STATus:QUEStionable:ENABle?
Returns
< value >
STATus:QUEStionable:PTRansition
This command set the value of the Questionable PTR(Positive-Transition)
register.The register serve as polarity filters between the Questionable Condition
and Questionable Event registers to cause the following actions.
When a bit of Questionable PTR register is set to 1,then a 1-to-0 transition of
the corresponding bit of the Questionable Condition register causes that bit in
the Questionable Event register to be set.
Command syntax
STATus:QUEStionable:PTRansition <value>
Arguments
<value> 0~65535
Example
STATus:QUEStionable:PTRansition 128
Query syntax
STATus:QUEStionable:PTRansition?
Returns
<value>
STATus:QUEStionable:NTRansition
This command set the value of the Questionable NTR(Negative-Transition)
register.The register serve as polarity filters between the Questionable Condition
and Questionable Event registers to cause the following actions.
When a bit of Questionable NTR register is set to 1,then a 1-to-0 transition of
the corresponding bit of the Questionable Condition register causes that bit in
the Questionable Event register to be set.
Command syntax
STATus:QUEStionable:NTRansition <value>
Arguments
<value>0~65535

Table of Contents