System Commands
Copyright© Itech Electronic Co., Ltd. 57
mode.
Command syntax
[SOURce:]NORMal:SYNC <DISable|ENABle>
Arguments
<DISable|ENABle>
ENABle: indicates in balance mode
DISable: indicates in Unbalance mode
Query syntax
[SOURce:]NORMal:SYNC?
Returns
<DISable|ENABle>
[SOURce:]NORMal:VOLTage:AC[:LEVel][:IMMediate][:
AMPLitude]
This command is used to set the AC voltage of a phase.
Command syntax
[SOURce:]NORMal:VOLTage:AC[:LEVel][:IMMediate][:AMPLitude] <A>,<float>
Arguments
<A>
<float> AC Voltage value
Query syntax
[SOURce:]NORMal:VOLTage:AC[:LEVel][:IMMediate][:AMPLitude]?
<A|B|C|ALL>
Returns
<float>
[SOURce:]NORMal:VOLTage:AC:LIMit[:LEVel]
This command is used to set the AC maximum and minimum voltages.
Command syntax
[SOURce:]NORMal:VOLTage:AC:LIMit[:LEVel]
<A>,<MINimum|MAXimum>,<float>