System Commands
Copyright© Itech Electronic Co., Ltd. 37
MEASure[:SCALar]:CURRent:HARMonics:DISTort?
FETCh[:SCALar]:CURRent:HARMonics:DISTort?
This command is used to read the real-time measured current distortion of a
harmonic.
Command syntax
MEASure[:SCALar]:CURRent:HARMonics:DISTort? <A|B|C>,<TOTal|value>
FETCh[:SCALar]:CURRent:HARMonics:DISTort?<A|B|C>,TOTal|ALL|order
Arguments
<A|B|C>,
<TOTal| value>
Returns
<float>
MEASure[:SCALar]:PHASe:HARMonics?
FETCh[:SCALar]:PHASe:HARMonics?
This command is used to read the harmonic of a phase.
Command syntax
MEASure[:SCALar]:PHASe:HARMonics?<A|B|C>,<ALL|value>,<U|I>
FETCh[:SCALar]:PHASe:HARMonics?<A|B|C>,ALL|order,U|I
Arguments
<A|B|C>,
<ALL|value>,
<U|I>
Returns
<float>
MEASure[:SCALar]:FREQuency:HARMonics:FUNDam
ental?
FETCh[:SCALar]:FREQuency:HARMonics:FUNDament
al?