EasyManuals Logo
Home>ITech>Power Supply>IT7600 Series

ITech IT7600 Series User Manual

ITech IT7600 Series
103 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #30 background imageLoading...
Page #30 background image
System Commands
Copyright© Itech Electronic Co., Ltd. 17
mode(control from panel). In this mode ,all of keys on front panel is valid.
Command syntax
SYST:LOC
Arguments
None
Query syntax
None
SYSTem:RWLock
This command is transmit through interface, the same function as
SYST:REM,but the difference is: this command can lock “LOCAL” button
as well. When this command is executed, the “Local” button can’t switch
to local control mode.
Command syntax
SYSTem:RWLock
Arguments
None
Returns
None
SYSTem:DATE
This command is used to set the system date.
Command syntax
SYSTem:DATE < value >,< value >,< value >
Arguments
<value> yy
<value> mm
<value> dd
Example
SYSTem:DATE 2015,5,22
Query syntax
SYSTem:DATE?

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT7600 Series and is the answer not in the manual?

ITech IT7600 Series Specifications

General IconGeneral
BrandITech
ModelIT7600 Series
CategoryPower Supply
LanguageEnglish

Related product manuals