System Commands
Copyright© Itech Electronic Co., Ltd. 58
<MINimum|MAXimum>
<float>
Query syntax
[SOURce:]NORMal:VOLTage:AC:LIMit[:LEVel]?
<A|B|C|ALL>,<MINimum|MAXimum>
Returns
<float>
[SOURce:]NORMal:VOLTage:DC[:LEVel][:IMMediate]
This command is used to set the DC voltage of a phase.
Command syntax
[SOURce:]NORMal:VOLTage:DC[:LEVel][:IMMediate]
<A>,<float>
Arguments
<A>
<float> DC Voltage value
Query syntax
[SOURce:]NORMal:VOLTage:DC[:LEVel][:IMMediate]? <A|B|C|ALL>
Query syntax
<float>
[SOURce:]NORMal:VOLTage:DC:LIMit[:LEVel]
This command is used to set the DC maximum and minimum voltage.
Command syntax
[SOURce:]NORMal:VOLTage:DC:LIMit[:LEVel]
<A|B|C|ALL>,<MINimum|MAXimum>,<float>
Arguments
<A|B|C|ALL>
<MINimum|MAXimum>
<float>
Query syntax
[SOURce:]NORMal:VOLTage:DC:LIMit[:LEVel]?
<A|B|C|ALL>,<MINimum|MAXimum>