System Commands
Copyright© Itech Electronic Co., Ltd. 13
Returns
<value>
Related Command
STATus:OPERation:ENABle
STATus:OPERation:ENABle
This command can set the parameter of operation event enable register. Setting
parameter can determine which bit value of operation event register is 1 and the
bit will cause OPER of status byte register to be 1.
Command syntax
STATus:OPERation:ENABle <value>
Arguments
<value> 0~65536
Example
STATus:OPERation:ENABle 128
Query syntax
STATus:OPERation:ENABle?
Returns
<value>
STATus:OPERation:PTRansition
This command set the value of the Operation PTR(Positive-Transition)
register.Setting parameter can determine which bit value of operation event
register is 1 and the bit will cause OPER of status byte register to be 1.
Command syntax
STATus:OPERation:PTRansition <value>
Arguments
<value> 0~65535
Example
STATus:OPERation:PTRansition 128
Query syntax
STATus:OPERation:PTRansition?