E93
.
• .
•
( 3.3.1).
E141
1
.
.
• .
E144
CRC EEPROM 1 2.
E145
.
E341
2
.
.
• .
E360 E398
.
• .
.
E900
.
E901
.
E93
The width gauge arm is defective.
• Call service.
• As long as the gauge arm is defective, enter
distance and nominal rim dimensions by pressing
the function keys and rotating the wheel ( 3.3.1).
E141
The content of the number 1 permanent memory is not
reliable. The balancing can only be performed in certain
conditions.
• Call technical support.
E144
The CRC of the EEPROM 1 and 2 are incorrect.
E145
The contents of both permanent memories are different,
but both contain valid data.
E341
The content of the number 2 permanent memory is not
reliable. The balancing can only be performed in certain
conditions.
• Call technical support.
from E360 to E398
The Cameras system is not operating correctly.
• Switch the machine off and back on. If the problem
persists, call technical support.
E900
Unknown machine model.
E901
The machine is not calibrated.