Initially Configuring the ACX1000 or ACX1100 Router on page 117
Configuring External Clock Synchronization for ACX Series Routers
6. Issue the show chassis synchronization command to check the status of the port.
user@host> show chassis synchronization
Clock Synchronization Status :
Clock module on CB 0
Current state : master
Current clock state : internal
Selected for : 13 days, 23 hours, 15 minutes, 17 seconds
Selected since : 2012-10-29 18:28:35 EDT
Deviation (in ppm) : +0.00
Last deviation (in ppm): +0.00
Clock Synchronization Status :
Clock module on CB 1
Current state : backup
Current clock state : locked to master CB
Selected for : 13 days, 23 hours, 14 minutes, 23 seconds
Selected since : 2012-10-29 18:29:29 EDT