EasyManua.ls Logo

Juniper ACX1000 - Table 18: Router Environmental Specifications

Juniper ACX1000
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 18: Router Environmental Specifications
ValueDescription
No performance degradation to 10,000 ft (3048 m)Altitude
Normal operation ensured in relative humidity range of 5% to 90%,
noncondensing
Relative humidity
Harsh environment: –40°F (–40°C) to 149°F (65°C)
Central office environment: 23°F (–5°C) to 131°F (55°C)
Temperature
Harsh environment: –40°F (–40°C) to 122°F (50°C)
Central office environment: –40°F (–40°C) to 104°F (40°C)
Commercial grade
SFP/SFP+ temperature
Designed to meet Telcordia Technologies Zone 4 earthquake
requirements
Seismic
Harsh environment:
1GB ports: Full traffic
10GB ports: Full traffic 1G ports
T1/E1 ports: Full traffic
SFP/SFP+: Extended temperature grade or industrial grade
Central office environment:
1GB ports: Full traffic
10GB ports: Full traffic 1G ports
T1/E1 ports: Full traffic
SFP/SFP+: Extended temperature grade or industrial grade
Configuration
NOTE: Install the routeronly in restricted areas,such as dedicated equipment
rooms and equipment closets, in accordance with Articles 110-16, 110-17, and
110-18 of the National Electrical Code, ANSI/NFPA 70.
Related
Documentation
Chassis Physical Specifications for ACX1000 and ACX1100 Routers
49Copyright © 2017, Juniper Networks, Inc.
Chapter 5: Preparation Overview

Table of Contents

Other manuals for Juniper ACX1000

Related product manuals