EasyManua.ls Logo

Kamstrup ULTRAFLOW 54 Series - Installation Examples (Mechanical); MULTICAL Mounted on ULTRAFLOW 54 (H); Installation on an Ascending Pipe; Installations at Eye Level or Higher

Kamstrup ULTRAFLOW 54 Series
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ULTRAFLOW®54(H)/(J)
KamstrupA/S∙TechnicalDescription∙5512‐1554_J1_GB_04.2018
25
7.5 Installation examples (mechanical)
MULTICAL
®
602/6L2/603 and by means of installation fitting 3026-857 even MULTICAL
®
801 can all directly be
mounted on top of ULTRAFLOW
®
54 (H)/(J).
7.5.1 MULTICAL
®
mounted on ULTRAFLOW
®
54 (H)
7.5.1.1 Installation on an ascending pipe
Figure 13. MULTICAL
®
mounted on ULTRAFLOW
®
mounted on an ascending pipe.
When installing ULTRAFLOW
®
on an ascending pipe, it can be of advantage to turn ULTRAFLOW
®
±360° around the
pipe axis to optimize the readability of the MULTICAL
®
display at direct mounting of MULTICAL
®
on ULTRAFLOW
®
.
7.5.1.2 Installations at eye level or higher
Figure 14. MULTICAL
®
mounted on ULTRAFLOW
®
when installed at eye level or higher.
In case of installations above eye level, it can be of advantage to turn ULTRAFLOW
®
-45° downwards to optimise
the readability of the MULTICAL
®
display at direct mounting of MULTICAL
®
on ULTRAFLOW
®
.