EasyManuals Logo

Keithley 2600a series User Manual

Keithley 2600a series
696 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #501 background imageLoading...
Page #501 background image
2600AS-901-01 Rev. B / September 2008 Return to Section Topics 19-179
Series 2600A System SourceMeter® Instruments Reference Manual Section 19: Remote Commands
status.operation.instrument.trigger_timer.trigger_overrun.condition
status.operation.instrument.trigger_timer.trigger_overrun.enable
status.operation.instrument.trigger_timer.trigger_overrun.event
status.operation.instrument.trigger_timer.trigger_overrun.ntr
status.operation.instrument.trigger_timer.trigger_overrun.ptr
Attribute Operation status trigger timer overrun register set.
Default 0
TSP-Link
accessibility
This attribute can be accessed from a remote TSP-Link node.
Usage Reads condition, enable, event, NTR, and PTR registers:
operreg =
status.operation.instrument.trigger_timer.trigger_overrun.condition
operreg =
status.operation.instrument.trigger_timer.trigger_overrun.enable
operreg =
status.operation.instrument.trigger_timer.trigger_overrun.event
operreg =
status.operation.instrument.trigger_timer.trigger_overrun.ntr
operreg =
status.operation.instrument.trigger_timer.trigger_overrun.ptr
Writes to enable, NTR, and PTR registers:
status.operation.instrument.trigger_timer.trigger_overrun.enable =
operreg
status.operation.instrument.trigger_timer.trigger_overrun.ntr =
operreg
status.operation.instrument.trigger_timer.trigger_overrun.ptr =
operreg
Set operreg to one of the following values:
0 Clears all bits.
status.operation.instrument.trigger_timer.trigger_overrun.TMR1
Sets TMR1 bit (B1).
status.operation.instrument.trigger_timer.trigger_overrun.TMR2
Sets TMR2 bit (B2).
status.operation.instrument.trigger_timer.trigger_overrun.TMR3
Sets TMR3 bit (B3).
status.operation.instrument.trigger_timer.trigger_overrun.TMR4
Sets TMR4 bit (B4).
status.operation.instrument.trigger_timer.trigger_overrun.TMR5
Sets TMR5 bit (B5).
status.operation.instrument.trigger_timer.trigger_overrun.TMR6
Sets TMR6 bit (B6).
status.operation.instrument.trigger_timer.trigger_overrun.TMR7
Sets TMR7 bit (B7).
status.operation.instrument.trigger_timer.trigger_overrun.TMR8
Sets TMR8 bit (B8).
operreg can also be set to the decimal weight of the bit to be set. Example:
To set bit B6 (TMR6), set operreg to 64 (2
6
).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2600a series and is the answer not in the manual?

Keithley 2600a series Specifications

General IconGeneral
BrandKeithley
Model2600a series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals