OUTPut:PROTection:OT:AMBient:MARGin?
Returns the difference between the factory ambient over-temperature setting and the ambient
temperature at the front panel air inlet. The margin is returned in degrees Celsius.
Parameter Typical Return
(none) (none)
Returns the temperature margin: OUTP:PROT:OT:AMB:MARG?
l
The factory over-temperature setting is 55° C and the ambient temperature is 25° C.
OUTPut:PROTection:OT:TUNNel:MARGin? (@<chanlist>)
Returns the difference between the factory heatsink over-temperature setting and the power module
heatsink temperature. The margin is returned in degrees Celsius.
Parameter Typical Return
<chanlist> one or more channels (none)
Returns the temperature margin for channel 1: OUTP:PROT:OT:TUNN:MARG? (@1)
l
The factory over-temperature setting is 100° C and the ambient temperature is 25° C.
5 SCPI Programming Reference