FlexRay Triggering and Serial Decode 27
Keysight InfiniiVision 3000T X-Series Oscilloscopes User's Guide 435
2 In the Search Menu, press the Search softkey; then, turn the Entry knob to select
the serial bus (Serial 1 or Serial 2) on which the FlexRay signals are being
decoded.
3 In the Search Menu, press Search for; then, select from these options:
• Frame ID — Finds frames with the specified ID. Press the Frame ID softkey to
select the ID.
• Cycle number (+ Frame ID) — Finds frames with the specified cycle number and
ID. Press the Frame ID softkey to select the ID. Press the Cycle # softkey to
select the number.
• Data (+ Frame ID + Cycle number) — Finds frames with the specified data, cycle
number, and frame ID. Press the Frame ID softkey to select the ID. Press the
Cycle # softkey to select the number. Press the Data softkey to open a menu
where you can enter the data value.
• Header CRC Error — Finds cyclic redundancy check errors in headers.
• Frame CRC Error — Finds cyclic redundancy check errors in frames.
• Errors — finds all errors.
For more information on searching data, see “Searching Lister Data" on page 152.
For more information on using the [Navigate] key and controls, see “Navigating the
Time Base" on page 75.