I2C/SPI Triggering and Serial Decode 28
Keysight InfiniiVision 3000T X-Series Oscilloscopes User's Guide 447
 
In the SPI Master-Out Slave-In Menu:
a Press the MOSI Data softkey; then, turn the Entry knob to select the channel 
that is connected to a SPI serial data line. (If the channel you selected is off, 
switch it on.)
The MOSI label for the source channel is automatically set.
b Press the Threshold softkey; then, turn the Entry knob to select the MOSI 
signal threshold voltage level.
The threshold voltage level is used in decoding, and it will become the 
trigger level when the trigger type is set to the selected serial decode slot.
7 (Optional) Press the MISO softkey to open the SPI Master-In Slave-Out Menu.
In the SPI Master-In Slave-Out Menu:
a Press the MISO Data softkey; then, turn the Entry knob to select the channel 
that is connected to a second SPI serial data line. (If the channel you 
selected is off, switch it on.)
The MISO label for the source channel is automatically set.
b Press the Threshold softkey; then, turn the Entry knob to select the MISO 
signal threshold voltage level.
The threshold voltage level is used in decoding, and it will become the 
trigger level when the trigger type is set to the selected serial decode slot.
8 Press the CS softkey to open the SPI Chip Select Menu.