Detector Switches
(c) Insert a 5 x 7 inch sheet of film.
Adjustment of the Detector Switches
(d) Move the drive side DETECTOR
SWITCH until the REPLENISHMENT
PUMP activates.
(e) Check that the REPLENISHMENT
Moving parts.
PUMP stops in 3 seconds after you
remove the sheet of film.
[1] Remove the TOP COVER.
[6] Adjust the clearance between the MAGNET
[2] Check the DEVELOPER RACK and the
and the DETECTOR SWITCH if necessary.
DETECTOR CROSSOVER ASSEMBLY for
(a) Loosen the SCREW.
squareness. See pages 2-6 and 2-7.
(b) Move the ROCKER ARM.
[3] Install the DEVELOPER RACK and the
DETECTOR CROSSOVER ASSEMBLY.
(c) Tighten the SCREW.
[4] Set the clearance between the MAGNET and
[7] Do steps 4 - 6 to adjust the DETECTOR
the DETECTOR SWITCH on the drive side to
SWITCH on the non-drive side.
1.6 mm (0.06 or 1/16 in.).
[8] Install the TOP COVER.
[5] Check the clearance between the MAGNET
[9] Check that the REPLENISHMENT PUMP
and the DETECTOR SWITCH:
does not operate unless you feed film.
(a) Energize the processor.
(b) Lift the top DETECTOR ROLLER.
1.6 mm
(0.06 in.)
H112_0112BA
H112_0112BCA
SWITCH (2)
DETECTOR
MAGNET (2)
SCREW
SWITCH (2)
DETECTOR
ROLLER
DETECTOR
ROCKER ARM
ROCKER
ARM
Adjusting the Detector Switches
2-4 981777