Plumbing
General
[1] Check all the CONNECTIONS to the RECIRCULATION PUMPS, the VALVES, TUBING, and TANKS for
leakage.
[2] Check that the temperature of all incoming water is 4 - 30°C (40 - 85°F).
[3] Check the flow rate of the wash water.
(a) Drain the TANKS.
(b) Remove the:
FIXER/WASH CROSSOVER ASSEMBLY
DRYER RACK ASSEMBLY
WASH RACK ASSEMBLY
(c) Turn on the water.
(d) Measure the flow rate of the water. It should be 946 mL/min (
1
4
gal/min), +10% -0%, from the
WATER INLET TUBE.
H112_0070DA
WEIR (3)
H112_0070DCA
TANK (3)
WATER
INLET
TUBE
3-10 981777