Replacement of the Developer Heater
[1] Disconnect the main power.
[2] Drain the DEVELOPER TANK or clamp the 2 TUBES to the THERMOWELL.
[3] Disconnect the wires to the DEVELOPER HEATER at TB2-9 and TB2-10.
When you remove the DEVELOPER HEATER from the THERMOWELL, a small amount of
developer may spill. Clean any spilled solution.
[4] Remove the:
• 2 SCREWS
• THERMOWELL
• DEVELOPER HEATER from the THERMOWELL
H112_0099BA
H112_0099BCA
SCREW (2)
TUBE
TUBE
HEATER
DEVELOPER
TANK
DEVELOPER
Removing the Thermowell
2-28 981777