Kodak M35 - Replenishment Pump

Kodak M35
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Replenishment Pump
Replacement of the Replenishment Pump
Dangerous voltage.
[1] Disconnect the main power.
[2] Disconnect the water supply.
[3] Remove the:
TOP COVER
2 SIDE PANELS
RECEIVING BIN
DRYER TEMPERATURE CONTROL KNOB
PUMP COVER
EXIT PANEL
H112_0115AC
DRYER
EXIT PANEL
TOP COVER
PUMP
COVER
SIDE PANEL (2)
TEMPERATURE
CONTROL KNOB
H112_0115ACB
[4] Disconnect the 2 MOTOR LEADS TB3-6 and
TB3-2 and the ground wire.
[5] Clamp the REPLENISHER TUBE.
[6] Remove the REPLENISHER TUBE LINES from the REPLENISHMENT PUMP.
[7] Remove and keep the 2 SCREWS, the 2 WASHERS, and the 2 LOCK WASHERS.
[8] Remove the REPLENISHMENT PUMP.
[9] Reverse the above procedure to install a new REPLENISHMENT PUMP.
H112_0097BA
H112_0097BCA
PUMP (2)
REPLENISHMENT
WASHER (2)
WASHER (2)
LOCK
SCREW (2)
TUBE LINES
REPLENISHER
Replacement of a Replenishment Pump